This article applies to:
OS: Windows, Linux
Product edition: Phoenix
Problem description
The Phoenix Management Console displays an error message:
Server is not able to connect to TurboTier for backup / restore.
However, the TurboTier connection status appears green on the console. The TurboTier service also appears running and sometimes, the following message appears in the logs:
βCould not connect to TurboTier server.
Traceback
The TurboTier logs contain:
[Errno 10013] An attempt was made to access a socket in a way forbidden by its access permissions
Cause
This issue occurs when the port 443 used by an application other than Phoenix TurboTier. There is a conflict of the port as Phoenix TurboTier also tries to use the same port for communication.
Resolution
Run below command prompt to check the port usage. The command will list the ports in use.
βnetstat -anCheck if the server has IIS role installed. Stop the IIS service if it is running. This will release the 443 port.
Restart the TurboTier service
For CC R1: Restart the Phoenix TurboTier service
βCommand is :service PhoenixCacheServer restartFor CC R3/R4: Restart the Druva Cache Server service
βCommand is :systemctl restart Druva-EnterpriseWorkloads.service
This will resolve the issue and backups will resume successfully.
This will resolve the issue and backups will resume successfully.
π Note
β Install the IIS role and Druva TurboTier on different servers.