Skip to main content

VMware backups to TurboTier fail with PHOENIX82 error

Updated today

This article applies to:

  • Product edition: Phoenix

Problem description

VMware backup jobs to TurboTier fail with PHOENIX82 error. The error is logged under Phoenix.log of the VMware backup proxy and PhoeixTurboTier.log.

Cause

TurboTier server is configured with incorrect time zone.

Traceback

Backup Proxy logs:

[2019-05-02 15:10:52,689] [INFO] Error Connecting to cache server. Error:Request not found on Phoenix server, validation failed. (#100000052) (Error Code : PHOENIX82) Retrying...[8][2019-05-02 12:35:12,920] [INFO] Error Connecting to cache server. Error:Request not found on Phoenix server, validation failed. (#100000052) (Error Code : PHOENIX82) Retrying...[9]

PhoenixTurboTier logs:

[2019-05-02 15:22:50,217] [INFO] [wpid 1231-1692-1556835387] Invalid token has been received for client authentication. ttime:1556835173.29. cache time 1556835770.22[2019-05-02 15:22:50,217] [ERROR] [wpid 1231-1692-1556835387] Encountered error before token was processed[2019-05-02 15:22:50,217] [ERROR] [wpid 1231-1692-1556835387] Error <class 'inSyncLib.inSyncError.SyncError'>:Request not found on Phoenix server, validation failed. (#100000052) (Error Code : PHOENIX82). Traceback -Traceback (most recent call last):

Resolution

Correct the time on the TurboTier server according to the local time zone.

PHOENIX82 does not indicate issues with network connection and ports between the backup proxy and TurboTier server.